What's in the box

The UNI 60 delivery contents, the damage inspection you must complete before accepting the boiler, and the parts you need to buy separately.

Updated

A UNI delivery contains the boiler assembly, the controller, the fan, the ash pan, a step-up transformer and a 220 VAC relay — and you must inspect all of it before you sign. After the sale, the distributor will not accept claims for incompleteness or mechanical damage.

Packing list

IDItemQty
1Boiler assembly1
2Controller (TIS Tronic 260U)1
3Fan1
4Ash pan1
5Step-up transformer1
6Relay 220 VAC1
7Temperature gauge

Why a transformer and a relay?

The controller and fan are 230 V devices. In North American installations the step-up transformer supplies them from a 120 V feed, and the 220 VAC relay block lets the 230 V pump outputs switch a 120 V circulator. Wiring for that is on the pump wiring page.

Inspect before you accept

Check the crate and the boiler body

Walk around the unit. Look for dents in the casing, damage to door faces, a bent flue collar, or a cracked controller housing. Photograph anything you find before unloading is complete.

Confirm it travelled upright

The boiler must be transported on the vehicle in the vertical position only. A unit that arrived on its side should be recorded on the delivery paperwork.

Count the loose items

Controller, fan, ash pan, transformer, relay. Missing items are far easier to resolve at delivery than a week later.

Check the doors and gaskets

Open each door. The sealing cord should be intact and seated. Door sealing cord is a consumable and is not covered by warranty, so a damaged cord found later becomes your cost.

Note damage on the delivery documents

Record any mechanical damage in writing at the time of delivery, and notify your distributor immediately.

Aesthetic vs functional damage

The distributor is not responsible for cosmetic damage during shipping. Mechanical damage that impairs the use of the boiler — a broken handle or controller, for example — will be repaired or replaced.

What you will also need

None of the following ships with the boiler, and the installation cannot be completed without them.

ItemWhyCovered in
Safety relief valveMandatory — the boiler must never run without onePiping
Expansion tankRequired on both open and closed systemsSystem design
Return-temperature protectionKeeps return water above ~130 °F to stop condensation and corrosionPiping
Buffer tankAbsorbs the heat of a full burn the building cannot use yetBuffer tank and hot water
Circulation pump(s)Central heating, and hot water if fittedPump wiring
PT1000 exhaust gas sensorNeeded for Brager Expert exhaust gases modeElectrical and sensors
Chimney / flue system8 in, acid-resistant stainlessChimney requirements
Chimney brush and scraperWeekly cleaning in mid-winterCleaning

MBtek sells matched components — boiler station, thermostatic protection valve, DHW tank and the UNI remote control — on the UNI 60 product page.